Premises Information

Return to Inspections
NameSOUTHWOOD CONDOMINIUMS
Address5813 SHARON ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/2/2017
Final Score @ Grade
10
General CommentsNote; Plexiglass has been installed (secured via screws) below the metal screening on the 3 non-compliant pedestrian gates. Although the plexiglass was installed on the interior sides of the gates (same side of the gates as the existing metal screening), the gates themselves are > 5' tall and no real step holds exist within 30" above the the upper horizontal member at the bottom of the gate. POOL PERMIT CAN BE ISSUED

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No -- Lattice brick wall and ~2" wide brick ledge on solid brick walls provide step holds. Curved ascending brick wall leading to double gate & retaining walls leading up to 2 other pedestrian gates provide step holds/ reduce over all outside approach to pool barrier to less than 48". -- Observed that wrought iron gate located between door to restrooms and chemical room is chained shut with lock in place; CPO reports that this gate stays locked & is never used. Although not a pedestrian gate, the gate is part of the overall pool barrier itself and lacks screening on its lower portion leaving exposed vertical members spaced > 4" a part and 2 horizontal members providing step holds; clearance under this gate is also > 4" ( at least 6"). ** See .2528 FENCES.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No -- No light fixture in chemical room. ** Provide. -- No natural cross draft ventilation or forced air ventilation in chemical room or equipment room. ** Provide.
27 2 Equipment room: filter backwash discharged through an air gap No No No Filter backwash pipe turns down into sump. ** Filter backwash water should discharge through a complete air gap.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow protection on hose bib located below mail boxes nor on hose bib in equipment room. ** Install vacuum breakers on hose bibs.