Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOUTHPOINT CONDOMINIUMS
Address960 SOUTHWEST DR
 
City/State/ZIP
DAVIDSON NC 28036
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/24/2026
Final Score @ Grade
12
General CommentsNO NIGHT SWIMMING. PERMIT RESTRICTION - PUMP MUST REMAIN AT 2650 RPM DUE TO TURNOVER. FLOW METER MUST REMAIN OPERABLE NOT TO EXCEED 80 GPM DUE TO RETURN RESTRICTION.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed plug missing in skimmer with disabled equalizer covers. CDI- plugged by CPO
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmers. CDI
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No discharge with air gap.