| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed ph at 7.1 |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Observed 1 weir missing. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
.2523(a) Provide depth markers on pool walls and pool deck at points of maximum and minimum depths. Observed depth markers missing on deep end of pool and side of pool deck greater than 25 feet apart. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Observed several bumpers missing on ladders. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed 3 missing inlet fittings. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
.2521(b) Provide at least 2" contrasting color band to edge of stair treads. Observed contrasting color band not provided at least 2 inches on stairs and wearing. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed ground level door leading to pool deck not self-closing, self latching or protected by audible alarm. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed deterioration around edge of pool on deck with sharp jagged edges and providing trip and cutting hazard. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. Observed pool phone not operable. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Observed equipment / chemical room not kept permanently locked. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. No air gap provided. |