Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHARON SOUTH
Address8437 KNIGHTS BRIDGE ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/8/2017
Final Score @ Grade
28
General Comments#6 --Pool filtration system has 2 identical pumps. Current PDSC form indicates that both pumps are Pentair, model #CFII-NI-5FE/ 5HP. EHS observed that both pumps have US 5HP replacement motors; however, the pumps do not match EHS pump field guide picture. No identifying information found on the outside of the pumps. J. Gaeckle present & removed the impellor cover from an identical model pump stored in equipment room and no make or model number could be found. Per J. Gaeckle, they are Pac-Fab 5HP pumps that are no longer manufactured. EHS unable to determine if the Pentair model# CFII-NI-5FE is an updated version of the pumps observed on-site today. ** Additional information on pumps needed. -- Current PDSC form indicates that the pool has 6 operable skimmer equalizers all w/ Aquastar 6HP covers. EHS observed 7 skimmers (all w/ Aquastar 6HP equalizer line covers on pool wall). No apparent signs observed that would indicate to EHS that one of the equalizer lines is inoperable. *** Submit new PDSC form to K. Wilson. K. Wilson must approve form. GC #8 One weir missing in skimmer located at deep end of pool. ** Obtain & install weir. INTENT TO SUSPEND ISSUED for #9 & #16.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Upper portion of pool wall tile (located at deep end of pool) is broken off . ** Replace wall tile.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Some deck depth markers and NO DIVING markers faded. ** Repaint. Intent to Suspend
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Both the men's & the women's restrooms are accessible from the pool deck and from the club house w/ fitness center. The doors that lead from the club house into the restrooms both have door knobs w/ latches & self-closing devices; however, the self-closing device on the women's door is no longer secured properly and the self-closing device on the men's restroom door needs adjusting. Both doors will not self-latch properly. ** Repair/ adjust both self-closing devices & verify that both doors properly self-close & self-latch. (Note: the other doors that lead from the restrooms into the pool enclosure have self-closing devices, but only have dead bolts.) Intent to Suspend
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed concrete chipped from pool deck near corner of pool closest to pool gated entrance and between storage building & wall leading to men's restroom. ** Maintain pool deck in condition where there are no offsets > 1/2".
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No -- Flow meter float stuck. ** Keep flow meter operational. -- Pool backwash water does not discharge inside the equipment room and the clear piece of piping on the backwash line serving as a sight glass is so etched that it is no longer useful. ** Install sight glass.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Equipment room/ chemical room has double doors that have a vent in the bottom of each side; however, the equipment room/ chemical room does not have any natural cross draft ventilation or forced air ventilation. ** Provide proper ventilation. See .2533(e) & .2534(3)
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash water discharges into storm drain at far right corner of parking lot (lot located to right side of the clubhouse & pool). ** Backwash water shall be discharged through a suitable air gap. See .2513 (b)
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Women's shower has leak @ "elbow" plumbing joint before shower head.. ** Resolve.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No -- Hose bib located inside equipment room/ chemical room has no back flow protection. ** Install vacuum breaker on hose bib. -- Over-the-rim fill spout extends ~5 1/2" beyond pool edge. ** Over-the-rim spout shall not protrude more than 2" beyond the edge of the pool.