| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Upper portion of pool wall tile (located at deep end of pool) is broken off . ** Replace wall tile. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Some deck depth markers and NO DIVING markers faded. ** Repaint. Intent to Suspend |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both the men's & the women's restrooms are accessible from the pool deck and from the club house w/ fitness center. The doors that lead from the club house into the restrooms both have door knobs w/ latches & self-closing devices; however, the self-closing device on the women's door is no longer secured properly and the self-closing device on the men's restroom door needs adjusting. Both doors will not self-latch properly.
** Repair/ adjust both self-closing devices & verify that both doors properly self-close & self-latch. (Note: the other doors that lead from the restrooms into the pool enclosure have self-closing devices, but only have dead bolts.)
Intent to Suspend |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed concrete chipped from pool deck near corner of pool closest to pool gated entrance and between storage building & wall leading to men's restroom. ** Maintain pool deck in condition where there are no offsets > 1/2". |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
-- Flow meter float stuck. ** Keep flow meter operational.
-- Pool backwash water does not discharge inside the equipment room and the clear piece of piping on the backwash line serving as a sight glass is so etched that it is no longer useful. ** Install sight glass. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Equipment room/ chemical room has double doors that have a vent in the bottom of each side; however, the equipment room/ chemical room does not have any natural cross draft ventilation or forced air ventilation.
** Provide proper ventilation. See .2533(e) & .2534(3) |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash water discharges into storm drain at far right corner of parking lot (lot located to right side of the clubhouse & pool).
** Backwash water shall be discharged through a suitable air gap. See .2513 (b) |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Women's shower has leak @ "elbow" plumbing joint before shower head.. ** Resolve. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
-- Hose bib located inside equipment room/ chemical room has no back flow protection. ** Install vacuum breaker on hose bib.
-- Over-the-rim fill spout extends ~5 1/2" beyond pool edge. ** Over-the-rim spout shall not protrude more than 2" beyond the edge of the pool. |