Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHARON LAKES CONDOMINIUMS
Address8301 SHARON LAKES RD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/24/2026
Final Score @ Grade
24
General Comments.2523(e) Provide a minimum of a two inch wide contrasting color band across the pool bottom at breakpoint. Observed breakpoint line needs repainting for 2027.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Observed depth markers completely faded at end of pool. CDI-9 FT spraypainted.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Provide at least one handrail on steps. Observed loose handrail.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed fence had >4 inch gap at bottom. CDI-mesh reattached .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed gate hinge has gate dropped slightly, intermittently self-latches. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed 2 doors inside deck not self closing self latching. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed window in office without alarm and opens >4 inches.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed emergency phone does not ring back. Tried with my cell, operators cell, land line and 911. Phone must ring back.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Flow meter be capable of measuring 1.5 times the design flow rate. Observed flow meter cannot be properly read since the bobber is above the measurement and against the cap.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed light not working in pump room. Repair.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer at hose bib.