General CommentsPERMIT RESTRICTION: VFD INSTALLED ON PUMP REQUIRED TO BE SET AT 60HZ. ONE FLOOR RETURN WITH AQUASTAR A10RCFRXXX COVER - NO SUCTION ON COVER NO NIGHT SWIMMING. *NOTE: Phone number listed on emergency telephone fading out. EHS had CPO re-write in sharpie so that it was easily legible.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed debris on pool floor. CPO cleaned out debris before end of inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed a few skimmer baskets full of debris. Keep skimmer baskets free of debris.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. Observed no depth markers along one whole side of the pool. Observed few of the present spray-painted depth markers fading out, no longer easily legible. Observed some of the present spray-painted depth markers exceeding 25ft within each other. Observed some of the NO DIVING spray-painted markers fading out. CPO had stencil kit in truck; other CPO drove to Walmart to grab spray paint; depth markers were fixed during inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed missing endcaps on 1 ladder located in diving area.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed no lighting inside pump room. Replace lightbulb so that there is lighting in pump room.