1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Main drains covered by leaves at time of inspection.
.2535(2) Main drains must be clearly visible from the pool deck. Operator cleared. Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladders missing slip-resistent tread.
.2521(b) Ladders shall have slip-resistant tread. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fencing with horizontals less than 45" in height and gaps greater than 4" in some areas. Main gate observed with gap greater than 4". Gate height starting to decrease 47.5" in some areas, due to hinges. Pool built 1990. Magna latch not catching at time of inspection. Two doors onto pool deck unable to be opened from vacant building, no longer in use with no key. Deadbolt only unlocks with key. Not able to physically unlock. Operator bent and adjusted fence to eliminate gap, raise for height and latch. Screwed pieces into doors that were unable to be checked because locked and cannot physically open, making part of wall. Advised fence/gate updates prior to 2021 pool season.
.2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed table within 6' of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Moved table. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Pool built 1990.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No backflow prevention on hose bibb. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. |