11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder ~7.5 inches from pool wall. ** Maintain between 3" and 6" maximum. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope that is part of ring buoy is dry rotted. ** Ring buoy replaced while on-site. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
- Fencing surrounding pool has vertical members spaced
> 4" a part.
- Outside approach to pool barrier reduced down to 42" in height as steps lead up to deck landing. Same problem exists at left end of fence @ outside approach on top of retaining wall.
** See .2528 Fences. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No forced air or natural cross draft ventilation in equipment & chemical room. ** Provide one or the other. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Sump built above grade & backwash pipe enters sump low @ side. ** Provide air gap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No backflow protection on hose bibs in restrooms & on deck. ** Install vacuum breakers on all hose bibs. |