| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing or damaged skimmer basket. Observed 1 skimmer basket damaged. -Pre Permit item |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Most no diving markers black and white or partially panted over. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. - Pre-permit item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook attached with zip ties. Must be securely attached with screws. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Pre-permit item. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Signage not posted at start of inspection, during inspection required signage was posted. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
One underwater light not fully installed, gap between light and pool wall. .2524(c) Lighting fixtures shall not present a hazard to the public. - Pre-permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Emergency phone not operating, when picked up no dial tone. No call back number posted on sign at phone. 2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2519(k) Provide operational pressure gauge on filter. Observed pressure gauge stuck at 40 PSI. -Pre Permit Item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(b) Provide sufficient lighting in pump room. Observed light not operating, corrected during inspection.
.2534(6) Provide sufficient lighting in chemical storage room. Observed light not operating, not corrected during inspection. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Restrooms renovated. No in-field plan review documentation that mirrors are shatterproof. .2526(k) Provide shatterproof mirrors. - Pre-permit item.
Hot water 116F. .2526(i) Water in restrooms shall not exceed 110 F.
No toilet paper in 1 restroom. .2526(l) Provide toilet paper and dispensers in restrooms. |
|
32
|
2
|
Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean |
No |
No
|
No |
Restrooms renovated. No in-field plan review documentation that tile floors are non-slip. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. - Pre-permit item. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Hose bib not observed in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. |