Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVIVO LIVING
Address8503 N TRYON ST
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/6/2026
Final Score @ Grade
40
General Comments*NOTE: No documentation was available during time of inspection that mirrors are shatterproof and tile floors are non slip Permit Restriction: Flow meter must remain operable. Flow shall be maintained between 67 gpm and 100 gpm to meet turnover and flow restriction of skimmer flow. Flow greater than 119 gpm is suction hazard. During time of inspection flow meter was verified at 92GPM at 2800 RPM. NIGHT SWIMMING NOT PERMITTED. *Senior EHS Will Harrison was present during time of inspection. Permit denied. Please contact Environmental Health office to pay revisit fee at 980-314-1620

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing or damaged skimmer basket. Observed 1 skimmer basket damaged. -Pre Permit item
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Most no diving markers black and white or partially panted over. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. - Pre-permit item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook attached with zip ties. Must be securely attached with screws. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Pre-permit item.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Signage not posted at start of inspection, during inspection required signage was posted.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One underwater light not fully installed, gap between light and pool wall. .2524(c) Lighting fixtures shall not present a hazard to the public. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Emergency phone not operating, when picked up no dial tone. No call back number posted on sign at phone. 2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2519(k) Provide operational pressure gauge on filter. Observed pressure gauge stuck at 40 PSI. -Pre Permit Item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed light not operating, corrected during inspection. .2534(6) Provide sufficient lighting in chemical storage room. Observed light not operating, not corrected during inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restrooms renovated. No in-field plan review documentation that mirrors are shatterproof. .2526(k) Provide shatterproof mirrors. - Pre-permit item. Hot water 116F. .2526(i) Water in restrooms shall not exceed 110 F. No toilet paper in 1 restroom. .2526(l) Provide toilet paper and dispensers in restrooms.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Restrooms renovated. No in-field plan review documentation that tile floors are non-slip. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. - Pre-permit item.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Hose bib not observed in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.