| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.1. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Most no diving markers black and white or partially panted over. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Handrail loose. .2521 Install handrails per manufacturer instructions.
Ladder loose. .2521 Install ladders per manufacturer instructions.
Ladder > 6” from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed new ring buoy with new 60 foot throw rope. .2530(a) Provide USCG approved ring buoy with attached 30 foot throw rope at least 1/4 inches in diameter. - Pre-permit item. - Marked length and where to cut rope.
Body hook attached with zip ties. Must be securely attached with screws. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with foothold at electrical box. .2528(b) Horizontals shall not be located less than 45" in height.
Magna-Latch slides up and down, doesn’t always latch. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Pre-permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
One underwater light not fully installed, gap between light and pool wall. .2524(c) Lighting fixtures shall not present a hazard to the public. - Pre-permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone does not ring when called. .2530(f) Emergency phone shall remain operable. - Pre-permit item.
Incorrect phone number posted at emergency phone. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Pre-permit item.
Flow meter not functioning. .2518(g) Keep flow meter operational. - Corrected. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Restrooms renovated. No in-field plan review documentation that mirrors are shatterproof. .2526(k) Provide shatterproof mirrors. - Pre-permit item.
Hot water 132.2F. .2526(i) Water in restrooms shall not exceed 110 F.
No toilet paper in restroom. .2526(l) Provide toilet paper and dispensers in restrooms. |
|
32
|
2
|
Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean |
No |
No
|
No |
Restrooms renovated. No in-field plan review documentation that tile floors are non-slip. .2526(c) Restroom floors shall be smooth to insure cleaning and slip-resistant. - Pre-permit item. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Hose bib not observed in restrooms. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose. |