Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVIVO LIVING
Address8503 N TRYON ST
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/24/2018
Final Score @ Grade
28
General Comments8. Floating weirs - approved by C.Sells Call to schedule night time inspection

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Missing cyanuric acid level readings, record 1 x week, level measured and recorded during inspection
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Remarked lettering in a couple tiles that had been painted over, recommend replacing or putting on stickers
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Tighten 1 ladder that is loose
22 6 Premises: emergency telephone provided No No No Posted correct dialing instructions during inspection
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Natural cross or continuous forced ventilation required, keep chemicals off floor
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Label valves & pipes
27 2 Equipment room: filter backwash discharged through an air gap No No No 2" air gap required on backwash line
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Mirrors should be shatter-resistant
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Backflow preventer required on hose bib
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Floors should be slip-resistant