3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Maintain PH levels 7.2-7.8. Observed PH at 7.0. (Immediate suspension issued) |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Maintain all equalizer covers in place. Must have new A112.19.8-2007 compliant covers on equalizer lines. Observed equalizer cover missing. (Immediate suspension). |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Maintain all weirs in place. Observed 1 out of 2 weirs missing from equalizers. 50% missing. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed both ladders loose. Observed 1 end cap missing on ladder. Replace |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Maintain 6ft clearance around pool deck. Observed lawn chairs as close as 3-4 ft from edge of pool. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Label directional flow on circulation pipes. Observed some pipes without labels and some faded. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Maintain water in restrooms no greater than 110F. Observed hot water in restrooms 121F. |