Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAMBERLAKE APARTMENTS
Address5826 REDDMAN ROAD
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/3/2025
Final Score @ Grade
28
General CommentsPERMIT DENIED for the following items on inspection sheet: 5, 6, 9, 12. For re-inspection call Main office at 980-314-1620 AFTER all 4 and 6 point demerits are corrected. Re-inspection fee is required.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed total alkalinity reagent expired. Permit denied.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. Observed skimmer closest to pump room with no equalizer cover. Permit denied.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed 3 ft depth marker and no diving marker fading. Re-paint. Permit denied.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one missing floor return and one cracked floor return. Replace. Permit denied.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope exceeding required length. CPO cut rope to required length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed door from leasing office not self closing. CPO repaired door, EHS observed door self closing. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed gap between verticals in fence exceeding 4 inches. Pool was constructed prep May 2010. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Observed horizontals on gate less than 45 inches apart. Horizontals were removed from gate.