1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
.2535(2) Main drains must be clearly visible from the pool deck. Observed main drain screws not visible and drain covers barely visible from pool deck. Permit denied. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. PERMIT DENIED |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed pool logs not including total alkalinity, cyanuric acid or main drain checks. PERMIT DENIED |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing or damaged skimmer basket. Observed 2 skimmer baskets damaged. PERMIT DENIED |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed missing floor return cover and wall cover. PERMIT DENIED. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope at 30ft, required length of rope is 45ft. PERMIT DENIED |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. Observed pool gate 45 inches tall measured from ground outside of barrier.
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed verticals on gates and sections of fencing more than 4 inches apart. Fencing is Pre-may 2010. Gate must be corrected.
.2528(a) Gate latches shall be 54" in height. Observed magna-latch only 48 inches from ground.
.2528(b) Gates may only swing toward pool if built prior to May 2010 and natural topography, landscape, or egress prevents the gate from swinging away from the pool. Observed gate swinging in towards pool, topography appears flat around gate area. CPO stated gate used to swing outwards away from pool.
PERMIT DENIED. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Observed emergency phone not operational during inspection. PERMIT DENIED |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2519(k) Provide operational pressure gauge on filter. Observed pressure gauge on filter not operational. |