15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope longer than 45 feet and not connected to ring buoy. CDI- adjusted to 45 feet and attached to buoy. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed some areas of fencing with greater than 4 openings. Pool built prior to 2010 so no permit action.
.2537(b) All gates and doors shall be self-closing, self-latching. Observed door leading to restrooms not self-latching. CDI- repaired.
.2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. Observed gate at 45 inches in height. No permit action as pool was built prior to 2010. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed trip hazard in pool deck. CDI- filled. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(e) Provide a spare basket for pump. Observed no spare pump basket. |