NameRAINTREE COUNTRY CLUB
Address8600 RAINTREE LANE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/8/2024
Final Score @ Grade
30
General CommentsNo night swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH 7.9 upon arrival. CDI- CPO adjusted chemicals and observed at 7.7 at second reading taken before end of inspection.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Documentation of yearly inspection required for Paddock main drain covers per directive from Katie Rudisill. CDI- CPO, Brandon Vaughn completed inspection of main drains during inspection. Letter provided.
13 4 Pool maintenance: contrasting band on steps and benches No No No .2521(b) Provide at least 2" contrasting color band to edge of stair treads. Observed portable stairs in shallow end of pool with color band faded/rubbed off. CDI- Stairs temporarily removed from the pool. Will verify that stairs have a painted color band prior to placing back in pool for use.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. Observed gate at far end of pool near snack bar not self-latching. CDI- gate was permanently disabled by adding a metal bar across gate/gate entrance. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed one door leading from clubhouse not self-latching. CDI- CPO installed an audible alarm during inspection.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed emergency phone not ringing when called back. CDI- CPO replaced phone with new phone.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observe flow meter not properly functioning. CDI- CPO repaired flow meter during inspection.