Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Pool pH measured 7.0 at beginning of inspection. CDI - Operator corrected to 7.2 during inspection. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. 4 missing weirs. Replace missing weirs. // .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Heavy debris in skimmer baskets. Clean baskets. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. 2 “no diving” markers were badly faded. CDI - Operator filled in no diving markers. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2517(a)3 Provide labeling affixed to diving equipment. Labels missing on diving boards. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. 1 ring buoy had a 60 foot rope attached and the other ring buoy had a 56 foot rope attached. CDI - Operator cut both ropes to 50 feet. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Automatic chlorine feeder pump would not shut off when pump was turned off. CDI - Operator corrected during inspection. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Air gap needed between bottom of pipe and top of backwash pit. |