Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back side of fence has another fence area creating less than 45" horizontal. Pool built 1974.
.2528(b) Horizontals shall not be located less than 45" in height. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals in same area as pump and equipment room. Items and small space not allowing 3' clearance around pump and piping. Pool built 1974. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water in restroom over 110 degrees F at time of inspection. .2526(i) Water in restrooms shall not exceed 110 F. |