NameQUAIL HOLLOW ESTATES FAMILY
Address7301 QUAIL MEADOW LN
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2026
Final Score @ Grade
14
General CommentsNo night swimming Flow meter must remain operable. Flow shall not exceed 170 GPM due to drain cover restrictions as a suction hazard

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed flow meter reading >170RPM after backwash. CDI-VSP RPM lowered flow meter reading 150 GPM. Make sure flow meter reading does not exceed 170GPM.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed foothold (metal bar attached to main gate) 28” above ground. CDI-signs attached to gate over sign. Keep sign in place
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. Observed no backflow preventer on hose bib on pool deck