| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Total alkalinity reagent expired. Replaced during the inspection. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Some debris/sand on pool floor. Keep clean. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Safety rope with all buoys on one side. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate with magnet latch measuring less than 45" from bottom horizontal. Repair prior to 2023 operating season.
Door from club on to pool deck not self-latching. Corrected during the inspection. Sliding glass doors not permanently affixed. Corrected during the inspection.
Retaining wall provides foothold on upper section of fence. Original construction. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator inlet. Operator will provide by end of business on 9/2 or permit action will be taken.
Pressure switch not operable on automated chlorinator. 300-29x with tablets during inspection. Do not use automated system until repaired. Once complete, contact Katie to schedule a return visit to verify chlorinator detects flow and operating correctly. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Forced draw ventilation not operable in pump room. Provide continuous forced draw. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. .2513(b) Filter backwash shall be discharged through an air gap.
When backwash occurs, floor drain line backs up with water. Requires repair prior to 2023 operating season. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No paper towels in restrooms. Corrected during the inspection. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No check valve on fill line in pump room. Original construction. Advise to provide ASSE 1013 check valve and installing with plumbing permit. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No floor drain/hose bib in restrooms. Original construction. |