NameQUAIL HOLLOW ESTATES ADULT
Address7301 QUAIL MEADOW LN
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 9/26/2022
Final Score @ Grade
34
General CommentsGeorge Oquendo present during the inspection. Onsite visit to pool for construction final, in-field plan review and permit inspection. Scope of Work: Installation of new stairs and handrails. New decking installed to be sloped away from pool. New pump and new filters installed in the pump room. Decking from ladder to far end of deep end and decking at step entry area repaired to slope to drain. Water tested during the inspection. not sloped to drain. Verified in-field plan review on previous inspection. Permit Restrictions: 1) Pump set at 3450 RPM with flow reading at 150 gpm. Flow meter must remain operable with flow at 150 gpm. 2) Polymeric sand must remain in place on pavers to ensure impervious surface. Fill line eliminate. Required to plumb fill line with check valve per Code requirement prior to 2023 operating season. Permit issued for no night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No cyanuric acid or total alkalinity readings. Record daily.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Debris on pool floor from work done on deck. Keep pool clean.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Safety rope with floats all to right side of pool.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Barrier at 44" near entry gate. Pool built pre-2010. Trees on exterior and paper towel dispenser on exterior of barrier provides foothold. Eliminate footholds.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool deck measures <6 ft. to perimeter wall at shallow end of pool. Maintain at least 6 ft. clearance around pool in all locations. Original construction.
22 6 Premises: emergency telephone provided No No No Emergency phone signage not secured to wall. Corrected during the inspection. Location of emergency phone not clearly visible. Written in on pool rules signage during the inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No light in pump room. Original construction. Wood removed from ventilation in side wall of pump room. Recommend installing a grate to keep vermin from entering the pump room. Pump room floor wet due to leak around top of filter. Tightened during the inspection.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line hard plumbed - original construction. Provide air gap for backwash line.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilet seat loose in men's restroom. Keep fixtures in good repair. Could not verify mirrors in restrooms as shatterproof. Mirrors shall be shatterproof.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention device on hose bib on pool deck. Provide backflow prevention device.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib or floor drains in pool restrooms or pump room. Provide hose bib and floor drains. Original construction.