Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed the chorine at 0. Corrected: Now at 3.
.2535(4) Maintain chlorine at least 1.0 ppm. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed four 4 inch skimmers and three 6 inch skimmers. Corrected: Now all skimmers are 6 inches.
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed the baskets and skimmers with debris. Clean.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed a loose ladder. Corrected: Tightened.
.2521 Install ladders per manufacturer instructions. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed the water in the restrooms at 120F.
.2626(i) Water in restrooms shall not exceed 110 F. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Observed hoses attached to outside faucets with no back flow prevention present. Provide.
.2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. |