Premises Information

Return to Inspections
NameWINSLOW APARTMENTS
Address7600 ANTLERS LANE
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/11/2023
Final Score @ Grade
10
General CommentsPool construction 1974. True maintenance gate is locked with a heavy chain and padlock. entry into the pool for swimmers is the properly working gate next to the stairs. Night swimming not permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed one missing weir. Due to age of pool not possible to replace.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed rear door of office area opening to pool deck self-closing but not self-latching and alarm did not work when tested. CDI, alarm repaired. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed greater than 4 inches under fence in some areas measuring 13 inches from grade to bottom horizontal. Pre-2010 construction.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. Door not able to completely shut and lock. .2533(b) Provide sufficient lighting in pump room. Light not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Observed no continuous or forced ventilation.