Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePEPPERTREE APARTMENTS
Address4335 CENTRAL AVENUE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/31/2026
Final Score @ Grade
16
General CommentsInspection completed with Luis Herrera and Joe Perez. Permit condition- flow meter must remain operable. Flow required at 63 GPM to meet turnover and flow restriction of the filter. Flow greater than 119 GPM exceeds the drain covers. Suction hazard. Notes- 1. Observed static during emergency phone call test. The 911 operator indicated there was no static on their end of the call. Recommend repairing so call quality is improved. 2. Observed no spare pump basket on site. Order a spare pump basket. 3. Add flow directional arrows to plumbing in pump room to indicate direction of flow.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed the pH at 7.0. CDI- adjusted to 7.2.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed windows leading from leasing area to pool deck not limited from opening more than 4 inches or audibly alarmed. CDI- windows were limited to open no greater than 4 inches. Observed 1 gate at back of property that leads onto pool deck locked. The maintenance personnel indicated they did not have a key to unlock this gate. CDI- gate was permanently disabled through use of screws and hardware.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed emergency phone number posted faded and not highly legible. CDI- phone number posted and made legible.