12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed equalizer covers missing. Operator found covers in pump room that were correct according to PDSC form. Fittings placed back into receptables. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed rope attached to ring buoy 15 ft. Operator bought rope that was 24 ft. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed door from gym to pool enclosure not self-latching. 30 days to correct. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
OLbserved flow meter not operating. Replace flow meter. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Observed directional arrows not present on pipes. |