Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePARK WALK
Address9467 S VICKSBURG PARK COURT
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/18/2017
Final Score @ Grade
22
General CommentsCPO reports deck lighting is insufficient for night swimming. CPO changed 2 pool signs correcting hours of operation from 10:00am to DUSK while EHS on-site. POOL PERMIT CAN BE ISSUED. Post pool permit in visible location on pool deck.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some etching & chipped areas on pool floor. ** Maintain in good repair.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No Safety rope hooks are not recessed in pool wall. ** See .2515(f). (Note: safety rope not present nor is one required.)
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No -- Chain link fence damaged in 3 areas near corner adjacent to tennis court entrance. ** 2 areas repaired while EHS on-site. Temporary means of correction made at 3rd area/ pool deck run off site; however, CPO reports he will take additional action.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No -- Deck cracks/( pieces of concrete missing) in 4 areas creating > 1/2" offsets. ** Corrected during inspection (CDI). -- Pieces of concrete missing & chunk of concrete missing from under side of coping at pool corner closest to equipment/ chemical room. ** CDI. -- Corner portion of pool deck closest to tennis court entrance has settled creating long deck crack & offset. ** Repair, resurface (or replace if necessary) deck in this area as soon as possible; otherwise, 2018 pool permit will be denied.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed high and low vents in equipment room/ chemical room double door; however, no natural cross draft ventilation or forced air ventilation present. ** See .2533(e) & .2534(3).
27 2 Equipment room: filter backwash discharged through an air gap No No No Filter backwash pipe inserted down into larger pipe in floor. ** Backwash water should discharge through a complete air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No -- Urinal leaking. ** Repair. -- Toilets dirty. ** Clean. -- Leak in ceiling in men's restroom. ** Resolve. -- Shower drain grate missing. ** Install grate.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in men's restroom does not have any back flow prevention. ** Install vacuum breaker.