| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH at 7.0. Maintain pH 7.2-7.8. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No written records. Record pH, chlorine, and main drain daily. Record CA/TA weekly. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer basket collecting debris. Clean. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Loose step handrail. Ladder rails missing plastic/rubber end caps. Tighten. Maintain end caps. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Vacuum line attachment in place in pool. Remove and provide proper flush fitting. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool deck furniture within 6' of pool. Maintain at least 6' clearance. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
No emergency phone on deck. Provide functioning phone. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Backwash line continuously running (when not in backwash mode). Repair. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No ventilation in pump room. Provide forced or cross ventilation. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap on backwash line. Maintain an air gap several inches above grade of floor. |
|