10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. EHS observed no safety rope at pool during inspection. This is required for the breakpoint, as the pool has a max depth of 9 feet. CDI - Operator installed safety rope with colored floats during inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). EHS observed pool chairs placed at a distance of 6 feet from the pool. Due to the pool being greater than >1600 sq ft, 8 feet of clearance is required. CDI - Operator removed chairs obstructed deck. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels. EHS observed piping and valves to pump for swimming pool without labels. CDI - Operator labeled all piping. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(m) Keep restrooms and fixtures clean and in good repair. EHS observed 2 out of three showers in women’s restroom in disrepair. |