11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder with missing rubber end caps. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed no cap/cover on vacuum suction line in pool wall. Suction line was not active during inspection. CDI- line was plugged. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed rope at 50 feet. CDI- adjusted to 35 feet. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Observed several sections of fencing with greater than 4 inches and up to approximately 9 inches underneath fencing. Recommend repairing to provide no more than 4 inches under fencing.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Observed one area of fencing under stairs to office where fencing was less than 48 inches as measured from outside of fencing. CDI- additional barrier was installed to correct. |