Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOAKS CONDOMINIUMS
Address1531 LANSDALE DRIVE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/26/2021
Final Score @ Grade
28
General CommentsCPOs Eric and Alex were present during the pool inspection. No signature occurred due to covid19 pandemic. Issuance of the pool permit does not negate meeting requirements of executive order 195 or subsequent orders in effect unless such orders are rescinded or suspended by another applicable order. No night swimming shall occur until another visit is made by the regulatory authority for approval.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. - Observed debris on pool floor. EHS was able to verify main drains and still see a majority of the pool floor. CDI- CPO started cleaning the pool during the inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Observed debris in skimmers during the inspection. CDI- CPO cleaned the skimmers during the pool.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No .2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. - Observed no breakpoint safety rope across the pool. CDI- CPO provided breakpoint rope by the end of the inspection.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Observed returns missing protective plastic. CDI- CPO repaired during the inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. - Observed 60ft throw rope. CDI- CPO provided 45ft throw rope by the end of the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Mesh shall not exceed 2.25" square. Provide no openings in fence and/or gate greater than 4"x4". - Observed mesh fence detached from pole near 3ft side. CDI- CPO repaired fence during the inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. - Observed standing water in pump room.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. - Observed no back flow prevention device on hose bib located near the pool.