8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some skimmers with debris in baskets. Keep clean. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Brick wall provides foothold at street entrance gate. Decorative cut-outs in condominium patio walls. Decorative cut-outs shall not exceed 1.75". Window limiters on windows could not be verified. Windows on to pool deck shall not open greater than 4". All items listed were not part of renovation and are original construction. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Electrical conduit provides trip hazard. Original constrution. Eliminate trip hazards. Permit Restriction - trash can or barrier must remain present next to conduit at all times pool is operational. Trash can in place at time of inspection.
5 1/2 ft. from pool to brick barrier. Original construction. Maintain 6 ft. of clearance around pool at all times.
Deck drains growing weeds in some locations. Did not observe standing water. May require repair in future inspections. Ensure deck is sloped to drain and drains properly. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Small leak on pipe in pump room. Leak does not appear to affect pool circulation. Pool chemistry ok and no pooling of water on pump room floor. Repair leak. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light in restroom not operational. Repair light.
Chemical storage room could not be accessed at time of inspection. Viewed on previous inspection. Provide storage to maintain chemicals up off pump room floor. |