Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOAKHILL APARTMENTS
Address831 BEATY STREET
 
City/State/ZIP
DAVIDSON NC 28036
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/19/2023
Final Score @ Grade
26
General CommentsInspection conducted with CPO Elvin Velez. Pre-permit inspection did not pass. 2) 6) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed some chlorine tabs in the skimmer. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Pressure gauge on Vac Alert SVRS system not functioning. .2539(b) Pools with single main drain or drains <36" apart shall provide a safety vacuum release system (SVRS) or other methods of preventing bather entrapment. Must be installed and operating per manufacturer’s instructions. - Pre-permit item. No place on log sheet for SVRS testing. .2539(b) SVRS systems shall be tested monthly per manufacturer’s instructions. - Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Hole in the deck by 5ft mark. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item.
18 4 Premises: lifeguards present or warning signs posted No No No Missing a word from safety signage. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Inadequate ventilation in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.