Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOAKHILL APARTMENTS
Address831 BEATY STREET
 
City/State/ZIP
DAVIDSON NC 28036
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 8/26/2015
Final Score @ Grade
28
General Comments22 - General Coment - 911 has 831 Beaty Street as address. When Polaris viewed, no assigned address listed. 835 Beaty St is building located across the street. Pool signage corrected to correct address. Will update in Polaris through GIS. Immediate Suspension issued for chlorine shock and pool rope.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Operator stated he had to shock pool in order to raise chlorine. Done two hours prior. Do not shock pool and keep pool open. Pool must be closed when chlorine put directly into pool. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No log book. Record chlorine, pH and main drain check daily. Alkalinity and acid weekly.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders >6" from pool wall. Maintain between 3" and 6" between ladder handrail and wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope damaged on ring buoy. Replace with 30 ft rope. Immediate Suspension issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck damage in several locations. Repair damage.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No ventilation in pump room. Provide continuous forced ventilation or cross ventilation.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap. Backwash line clear sight glass made of flexible piping. Provide hard PVC pipe.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels in restroom. Provide paper towels.