| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some damage to skimmer casing at 3 1/2 ft. Does not affect functionality of skimmer. Monitor damage and replace/repair if continues to worsen. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Painted No Diving markers <4" in height. Corrected during inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Some rust on ladders. Keep ladders in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Front gate with 2 1/2" under on left side. Corrected during inspection to 2".
Perimeter fencing ranging from 41" to 45" in height. Pool built prior to 2010. Fencing shall be at least 48" in height. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Pool furniture <6 ft from pool. Corrected during inspection.
Deck damage near 4 ft skimmer. Corrected during inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Pool built prior to 2010.
Lighting not operable in pump room. Provide lighting. Repeat non-compliance. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Labeling beginning to wear off on piping in pump room. Clearly identify all pipes with color codes/labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in mens restroom. Provide soap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Check valve without proper cross connection. Pool originally constructed with backflow installed for fill line. backflow. Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, a pipe-applied atmospheric vacuum breaker (ANSI/American Society of Sanitary Engineering No. 1001-1971), a pressure type anti-siphon vacuum breaker (ANSI/ASSE No. 1020-1976), or a reduced-pressure principle backflow preventer (ASSE No. 1013-1979, American
Water Works Association No. C506-1978), which are hereby adopted by reference in accordance with G.S. 150B-
14(c) or equivalent. |