Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWENDOVER GARDENS
Address2347 EASTWAY DRIVE
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 9/12/2025
Final Score @ Grade
44
General CommentsOSV to pool for permit inspection and in-field plan review with pump change. Verified the following during the inspection. 1) Permit Restriction: Flow meter must remain operable. Turnover cannot be met due to flow restriction of the filter. Flow shall be kept as close to 98 gpm as possible. Flow greater than 170 gpm exceeds main drains. Suction Hazard. 2) New Pump - Hayward Tristar VS 950, SP32950VSP meeting above permit restriction on Blue white flow meter. 3) Main drain and skimmer - actual 2.5"; return line - 2". 4) (2) Aquastar 2017 914xxx drain covers. 5) (3) skimmers with no EQ line covers. 6) Pentair TR100C filter rated for 98 gpm. 7) (8) wall returns. Pump approved. See inspection for items listed as Permit Denial items for items to correct prior to scheduling a return inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Operator not completing daily main drain checks. Record daily main drain checks to ensure drains are secure on the pool floor. Permit Denial.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Equalizer lines not plugged per State requirement inside the skimmer. Disabled on wall. Plug per State requirement. Permit denial. Main drains not flush to pool floor. Provides lip. Permit denial. PDSC form with incorrect number of skimmers listed. Pool has 3 skimmers. Update PDSC form to reflect accurate number. Permit denial.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No (1) of 3 skimmers missing weirs. Replace weir.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Grab rope on ring buoy degrading and rope too short. Provide new USCG approved ring buoy with 45 ft. rope. Permit denial.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Doors from main office with audible alarm. Doors shall self-close, with audible alarm or self-close, self-latch. Given to 2026 operating season to add self-closers.
22 6 Premises: emergency telephone provided No No No No dialing instructions at pool phone. Signage moved to reflect dial 911 during the inspection.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorine pucks in the skimmer baskets. Direct hazard to the public. Could not verify that the chlorinator was operable. Swimming pool shall be chlorinated through the feeder. No chlorine pucks in the skimmer baskets. Permit denial. Flow meter for chlorinator filled with chlorine and not operable. Flow meter shall be kept operable for NSF approval.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No spare pump basket for new pump. Provide spare pump basket. Permit denial.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Backwash pit pipe runs across pump room floor. Provide 3 ft. clearance around equipment.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No hose bib in restrooms. Original construction. Provide hose bib in restrooms.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Hose bib in pump room without backflow prevention. Provide backflow prevention device on hose bib.