| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Operator not completing daily main drain checks. Record daily main drain checks to ensure drains are secure on the pool floor. Permit Denial. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Equalizer lines not plugged per State requirement inside the skimmer. Disabled on wall. Plug per State requirement. Permit denial.
Main drains not flush to pool floor. Provides lip. Permit denial.
PDSC form with incorrect number of skimmers listed. Pool has 3 skimmers. Update PDSC form to reflect accurate number. Permit denial. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
(1) of 3 skimmers missing weirs. Replace weir. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Grab rope on ring buoy degrading and rope too short. Provide new USCG approved ring buoy with 45 ft. rope. Permit denial. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Doors from main office with audible alarm. Doors shall self-close, with audible alarm or self-close, self-latch. Given to 2026 operating season to add self-closers. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
No dialing instructions at pool phone. Signage moved to reflect dial 911 during the inspection. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorine pucks in the skimmer baskets. Direct hazard to the public. Could not verify that the chlorinator was operable. Swimming pool shall be chlorinated through the feeder. No chlorine pucks in the skimmer baskets. Permit denial.
Flow meter for chlorinator filled with chlorine and not operable. Flow meter shall be kept operable for NSF approval. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket for new pump. Provide spare pump basket. Permit denial. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Backwash pit pipe runs across pump room floor. Provide 3 ft. clearance around equipment. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No hose bib in restrooms. Original construction. Provide hose bib in restrooms. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Hose bib in pump room without backflow prevention. Provide backflow prevention device on hose bib. |