Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Observed one main drain cover, not fitting flush to the bottom of the pool. EHS was able to take the end of the Shepherd’s crook and wedge it underneath the opening which appears to be 3/8 to 1/2 an inch above the surface of the pool. This represents not only an entrapment hazard, but a change in the pattern of the flow that has not been tested. |