Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePARK HAVEN APARTMENTS
Address5821 REDDMAN ROAD
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/24/2025
Final Score @ Grade
40
General CommentsPermit denied For re-inspection call Main Office at 980-314-1620 AFTER all 4 and 6 point demerits are corrected. Re-inspection fee is required.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.0. Permit denied
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Observed test kit without reagents for total alkalinity. Permit denied. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed record logs without an area for weekly recordings of cyanuric acid and total alkalinity. Permit denied
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(c) The operator of the public swimming pool shall test an installed safety vacuum release system using the methodology and at the frequency recommended by the manufacturer, and the test dates and results shall be recorded in the written records required by Rule .2535(11) of this Section. Observed no recorded testing of SVRS. CPO tested SVRS during inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed damaged plaster on pool wall from missing ladder cap. Repair. Permit denied.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed skimmer missing weir. Replace weir. Permit denied.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed loose ladder. Observed ladder missing end cap.
13 4 Pool maintenance: contrasting band on steps and benches No No No .2521(b) Contrasting color band shall be clearly visible. Observed painted contrasting bands on stairs faded and worn off. Re-paint contrasting bands on stairs. Permit denied
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope longer than required length. CPO cut ring buoy rope to required length during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate to lefthand side when outside pool fence not latching. Observed door to clubhouse for restrooms not self closing self latching. Repair. Permit denied.