Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name59TWENTY @ MONROE
Address5920 MONROE RD
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/21/2025
Final Score @ Grade
14
General CommentsRe-inspection conducted with CPO Joshua Pineda present. PDSC information verified onsite. New safety vacuum release system (SVRS) installed and observed to be operable. Test dates and results recorded in chemical log record by CPO. No existing permit restrictions. All critical items from previous inspection observed in compliance during today’s site visit. Items observed today will not hold up permit. Permit sticker issued. Pool is not permitted for night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed rocks and rusting on plaster.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No 16 .2528(a) Provide no openings in fence and/or gate greater than 4". Observed opening measuring over 4.5” between vertices in part of fencing at exterior entrance. Pre-2010 construction.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No REPEAT VIOLATION: .2518(g) Keep flow meter operational. Flow meter is not operational. Repair/replace.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No REPEAT VIOLATION:.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bib missing its backflow preventer.