Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name59TWENTY @ MONROE
Address5920 MONROE RD
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/22/2025
Final Score @ Grade
52
General CommentsInspection conducted with CPO Joshua Pineda and EHS Hope McIntosh. Permit denied. Items denoted holding up permit: .2537(2) Observed trip hazards throughout pool deck. .2530(c) Observed “No Lifeguard on Duty” signage measuring at 2.5” lettering and worn. .2530(a) Observed rope for ring buoy not meeting requirement of 44”; rope length measured at 40”. .2537(8) Observed fitting detaching at 9 ft end of pool. .2539(b) SVRS observed to be non-operational during inspection. Once corrected return visit fee may be paid to Environmental Health at 980-314-1620.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) Pools with single main drain or drains <36" apart shall provide a safety vacuum release system (SVRS) or other methods of preventing bather entrapment. .2539(c) The operator of the public swimming pool shall test an installed safety vacuum release system using the methodology and at the frequency recommended by the manufacturer, and the test dates and results shall be recorded in the written records required by Rule .2535(11) of this Section. SVRS not being tested and observed to be non-operational during inspection. -6-
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed rocks and rusting on plaster. -4-
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed heavy debris in skimmers. -4-
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder at deep end of pool is very loose and leg of ladder missing it’s end cap. Install ladder to manufacturer’s instructions. REPEAT VIOLATION. -2-
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed fitting detaching at 9 ft end of pool. -4-
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy not meeting requirement of 44”; rope length measured at 40” during inspection. REPEAT VIOLATION. -6-
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No 16 .2528(a) Provide no openings in fence and/or gate greater than 4". Observed opening measuring over 4.5” between vertices in part of fencing at exterior entrance. Pre-2010 construction. -4-
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed decking in front of ladder is damaged and sharp. Damaged area is approximately 8” around. REPEAT VIOLATION. -4-
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed “No Lifeguard on Duty” signage measuring at 2.5” lettering and worn. -4-
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect phone number posted for emergency phone. CDI - Correct number verified and posted on signage. -6-
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter is not operational. Repair/replace. REPEAT VIOLATION. -4-
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Observed lightbulb in pump room is burnt out. REPEAT VIOLATION. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bib missing its backflow preventer. -2-
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2625(j) Observed glass soap dispensers in restrooms. Replace with materials made of plastic or metal. -2-