Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name59TWENTY @ MONROE
Address5920 MONROE RD
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/17/2019
Final Score @ Grade
18
General CommentsNo night swimming. Pool will close at dusk each day. Vac-alert system tested and functioning properly at time of inspection; main drain valve closed and pressure gauge on vac-alert immediately increased.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. One ladder loose and missing rubber bumper at bottom of rail. Repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope measured 33ft; rule requires 44ft throw rope for this pool. CDI - Staff purchased new rope from local pool supply store; rope cut to 44ft.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Two outside gates were not self closing or self latching. CDI - Both gates permanently closed; only access will be through the office.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Bobber in flow meter is stuck. CDI - Repaired by maintenance during the inspection.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No true air gap; bottom of discharge line extends below the top of the flood rim.