NameLATTA SQUARE
Address1101 E MOREHEAD ST
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/7/2020
Final Score @ Grade
30
General CommentsSkimmer equalizer covers expire September 2020. Replace and submit updated PDSC information for approval prior to expiration of covers. Permit will be suspended if covers are not approved and replaced prior to expiration. Unable to check windows from resident rooms onto pool deck at time of inspection. Ensure windows do not open greater than 4" onto pool deck or have audible alarm. No Night Swimming. Changed to "A" Open for Business, valid permit, with condition of staying closed to public by Executive Order-120, or other Orders, outlined in permit. Operator unable to sign due to COVID-19 protocol and safety precautions to not share equipment.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Some debris covering main drains. .2535(2) Main drains must be clearly visible from the pool deck. Operator cleaned and corrected.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records for pool at time of visit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Provided operator with record keeping forms and operator filled out. Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No New rope too long at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator corrected to 41'.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Brick by skimmer basket protruding more than 1/2" offset, loose creating trip hazard. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator replaced brick with a larger size and filled with epoxy to eliminate hazard. Deck is older and operator stated pool deck will be monitored for safety concerns and trip hazards throughout season to eliminate hazards. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not installed correctly or working. .2518(g) Keep flow meter operational. .2518(g) Install flow meter on return line per manufacturer instructions. Due to age of pool (built in '86), not able to install new flow meter correctly. Lack of severity does not warrant permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pool built in 1986. No chemical storage on site. Small leak causing standing water on floor. No 3' clearance around piping and equipment. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restroom fixtures dirty at time of inspection, but operable. .2526(m) Keep restrooms and fixtures clean and in good repair.