8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. 1 missing weir. Replace missing weir. // .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Baskets have debris in them. Clean. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. 1 ring buoy did not have throw rope. CDI - Operator removed it from pool. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Vacuum line cover was in backwards at start of inspection. CDI - Operator unscrewed it and placed it in port correctly. // .2518(g) Keep flow meter operational. Flow meter stuck. Repair or replace flow meter. |