Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePARK AT FERENTINO, THE
Address8061 WOODSCAPE DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/28/2021
Final Score @ Grade
24
General CommentsNight Swimming has not been approved.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.0. This was corrected and the pH was raised to 7.3.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace damaged skimmer lid. Observed entire round lid fixture at the deep end skimmer completely loose and can be easily pulled out of the skimmer well. The pool operator was able to secure the piece back into the wall.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed loose fittings on the ladders. This was corrected and the ladders were tightened down.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy rope length at 35ft. It should be 38ft. The rope was corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed the flow meter not properly working. This was corrected and the flow meter bobber was properly loosened and is now correctly bobbing.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap to the backwash discharge.