Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLAKESHORE VILLAGE CONDOMINIUMS
Address9043 J M KEYNES DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2026
Final Score @ Grade
18
General CommentsPermit Restriction: Flow meter must remain operable. Flow required at 80 gpm. Flow greater than 150 gpm exceeds the main drains. Suction Hazard. New Pump Hayward TristarVS 950, SP32950VSP, 2.7 thp FlowVis flow meter reading the above flow restriction at 80 gpm. (1) 2” main drain line; (2) 2” skimmer lines; (1) 2” return line (2) Aquastar 2017 1216xxx drain covers (4) skimmers with EQ lines disabled plugged in skimmer/plugged or plastered on wall. (4) floor returns (1) Pentair TR100C filter. EHS confirmed items during inspection. Construction: 1/1/1990 Rope: 45’

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. CPO worked on suction outlet cap during inspection. EHS confirmed cap was secure and in compliance.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope exceeded 45’ at initial portion of inspection. CPO cut and knotted rope during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed multiple offsets greater than 1/2”. CPO filled offsets during inspection to prevent trip hazards.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Pool chemicals stored on floor in storage.