16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed base of metal fencing rusted out where fencing attach into pool deck. Fencing is secured and no gaps greater than 4inches. Fencing will need to be repaired by next swimming pool season. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Repair pool deck near coping. Observed deck chipped near area where deck meets coping. Keep a six feet clearance around pool on pool deck. Observed pool chairs and tables too close. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Telephone was not working at time of inspection. TELEPHONE REPLACED AND PROPERLY WORKING AT TIME OF WRITE UP OF INSPECTION. SIGNAGE ON TELEPHONE PROPERLY LABELED AT TIME OF INSPECTION.
Check telephone often to make sure telephone is working. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Repair mechanical ventilation in pump/chemcial room. Mechanical ventilation in pump/chemical shall be continous. Remove paint, paint thinner and sink from pump room/chemical room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Label piping on pump system.---->flow of water
Monitor pH closely since chlorine is reading high. |