Water quality: pool water pH |
No |
No
|
No |
Observed pH @ 6.8. **pH raised to 7.2 while on-site. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Pool records lack weekly total alkalinity & cyanuric acid readings and daily main drain check. **Maintain complete pool records. CPO to start using MCHD pool record/ log form. (ITS) |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed scum on pool wall tiles. **clean. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Both skimmers missing weirs. **install. (ITS) |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
4 (of 6) international no diving symbols in black on white. **International symbol for no diving must be red & black on white background. See .2523(d). (ITS) |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed some chunks out of pool deck @ skimmer & @ junction with coping. **correct.
Observed wood/ baoards used at expansion joints (2) raised and/or splintered (@ pool deck). **correct.
Observed deck furniture as close as ~3' to 4' from pool edge. **Maintain 6' of clear walking space. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone inoperable & dialing instructions incorrect (sign states dial 911; however, lifting handset of phone will automatically dial/ call 911. **Phone replaced & correct dialing instructions posted while on-site. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Equipment/ chemical room has no cross ventilation & forced air vent is inoperable. **repair/ replace forced air vent. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water 120.4F in lobby restroom. **Maximum allowed is 110F.
Dispenser out of soap in lobby restroom. **Provide soap.
Lavatory clogged in lobby restroom. **Resolve. |