3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH was 8.0. CDI PIC adjusted 7.4 |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Observed sand and debris on pool floor. CPO started the cleaning process during inspection. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed some debris. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Provide at least one handrail on steps. Observed handrail unsecured. CDI PIC secured handrail |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed gap in fence greater than 4” X 4”. Pool built before 2010.
.2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches. Observed wall of concrete fencing with decorative cutouts greater than 1.75” |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed multiple lounge chairs closer than 6 ft to pool edge. CDI PIC moved chairs. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed pump “room” located outdoors without a ceiling, umbrella is covering the pump. Pool was constructed in 1965.
.2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. - No structure around pump and filter area. Umbrella installed over pump. Per state, construction of pool is 1965 and this is approved. |