Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameKIMBERLEE, THE
Address1300 REECE RD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/22/2026
Final Score @ Grade
26
General CommentsPermit Restrictions: Flow meter must remain operable. Flow shall not exceed 119 gpm due to main drain and equializer line Cover Flow restriction. Suction Hazard. Night Swimming NOT permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH was 8.0. CDI PIC adjusted 7.4
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed sand and debris on pool floor. CPO started the cleaning process during inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed some debris.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Provide at least one handrail on steps. Observed handrail unsecured. CDI PIC secured handrail
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed gap in fence greater than 4” X 4”. Pool built before 2010. .2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches. Observed wall of concrete fencing with decorative cutouts greater than 1.75”
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed multiple lounge chairs closer than 6 ft to pool edge. CDI PIC moved chairs.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Observed pump “room” located outdoors without a ceiling, umbrella is covering the pump. Pool was constructed in 1965. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. - No structure around pump and filter area. Umbrella installed over pump. Per state, construction of pool is 1965 and this is approved.