6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Provide approved PDSC documentation to the Health Department, use only approved fittings for main drain coverings and equalizer lines. The facility does not have an approved PDSC form. Observed a Paramount SDX Retro covering installed on an equalizer line. Permit immediately suspended. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Maintain ladders in good repair. Observed pool ladder without rubber endcaps installed. Observed the ladder not secured to the cement. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Maintain throw rope connected to ring buoy at 39 feet. Observed throw rope at 48 feet. CDI- rope was cut to 39 feet during inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Maintain a 6 foot unobstructed walkway around the pool deck. Observed furniture within 3 feet of the pool deck. CDI- furniture was moved during inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Maintain a flow meter on the filtered water line. Observed no flow meter installed. |