Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name6300 WOODBEND LLC
Address6320 WOODBEND DR
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/19/2026
Final Score @ Grade
4
General CommentsInspection conducted with Juan Compres. No night swimming. No violations noted. PERMIT RESTRICTION: Flow meter required operable. Flow required at 74 gpm due to filter flow restriction. Turnover not met at 112 gpm. Filter may require change if clarity issues occur. ITEMS VERIFIED DURING INSPECTION New Pump Pentair IntellifloVS + SVRS 011057, 3 hp pump Blue White flow meter reading within the range above. 2” main drain and skimmer line; 3” return line (coming out of the pump room floor). (2) Aquastar 2008 A10RCFRxxx drain covers. (4) skimmers with EQ lines disabled in skimmer and on wall. (1) Pentair TR100 filter (8) returns either on the wall or the floor.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Distance between fence horizontals measured at <30”. Pool constructed prior to 2010.