Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHUNTERS RUN
Address3200 SELWYN FARMS LANE
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/3/2022
Final Score @ Grade
4
General CommentsPermit restriction: Pump shall be set at 2855 gpm with restricted flow at 100 gpm due to return pipe restriction. Observed: Pump set at 2855 gpm with flow meter reading at 100 gpm due to return pipe size restriction. New Pump – Pentair Intelliflo VSF 011056, 3 hp pump. Blue White Flow meter installed on a 2” pipe. Flow meter should have >12” on inlet and >10” on outlet. Main drain – 3”; Skimmer – 3”; Return – 2” piping. (2) Aquastar A10RCFRxxx drain covers. (5) Aquastar 4HP equalizer line covers (2) Pentair TR140c filters 12 floor or wall returns

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Movable deck obstructions present.